SICK RLY3-OSSD100
| Features | |
|---|---|
| Applications | Output expansion module for OSSDs |
| Compatible sensor types | Safety sensors with OSSDs |
| Safety-related parameters | |
|---|---|
| Safety integrity level | SIL3 (IEC 61508)SILCL3 (IEC 62061) |
| Category | Category 4 (ISO 13849-1) |
| Performance level | PL e (ISO 13849-1) |
| PFHD (mean probability of a dangerous failure per hour) | 1.0 x 10-9 |
| TM (mission time) | 20 years (ISO 13849-1) |
| Stop category | 0 (IEC 60204-1) |
| Functions | |
|---|---|
| Path for external device monitoring (EDM) | Path for external device monitoring (EDM) |
| Interfaces | |
|---|---|
| Connection type | Front connector with spring terminals |
| Inputs | 2 safety inputs |
| Outputs | 2 enabling current paths (safe)1 feedback current path (for use as external device monitoring, not safe) |
| Display elements | LEDs |
| Electrical data – Operating data | |
|---|---|
| Voltage supply | Passive (no active voltage supply) |
| Power consumption (input circuits) | ≤ 1.5 W (DC) |
| Electrical data – Safety inputs | |
|---|---|
| Number | 2 |
| HIGH | 24 V DC (15 V … 30 V) |
| LOW | 0 V DC (–3 V … 5 V) |
| Input current | ≤ 50 mA |
| Test pulse width | ≤ 1 ms |
| Test pulse rate | ≤ 10 Hz |
| Electrical data – Enabling current paths | |
|---|---|
| Response time | 12 ms |
| Number | 2 |
| Type of output | N/O contacts, positively guided |
| Contact material | Silver alloy, gold flashed |
| Switching voltage | 10 V AC … 230 V AC10 V DC … 230 V DC |
| Switching current | 10 mA … 6 A |
| Total current | 12 A |
| Mechanical life | 1 x 107 switching cycles |
| Overvoltage category | III (EN 60664-1) |
| Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |