SCHMERSAL AES1265 (24VAC/DC)
SCMERSAL SAFETY RELAY
- 2 safety contacts, STOP 0
- Monitoring of BNS range magnetic safety sensors
| SPECIFICATIONS | |
|---|---|
| Enclosure material | Glass-fibre reinforced thermoplastic, ventilated |
| Material of the contacts, electrical | Ag-Ni 10 and 0.2 µm gold-plated |
| Gross weight | 174 g |
| Stop-Category | 0 |
| Wire breakage detection | Yes |
| Cross-circuit detection | Yes |
| Feedback circuit | Yes |
| Automatic reset function | Yes |
| Reset after disconnection of supply voltage | Yes |
| Earth connection detection | Yes |
| Integral system diagnostics, status | Yes |
| Number of LEDs | 1 |
| Number of normally closed (NC) | 2 |
| Number of normally open (NO) | 2 |
| Number of undelayed semi-conductor outputs with signaling function | 2 |
| Number of safety contacts | 2 |
| Number of signalling outputs | 2 |
| Performance Level, up to | d |
| Category | 3 |
| PFH value | 1.00 x 10⁻⁷ /h |
| Termination | rigid or flexibleScrew terminals M20 x 1.5 |
| Terminal designations | IEC/EN 60947-1 |
| Cable section, minimum | 0.25 mm² |
| Cable section, maximum | 2.5 mm² |
| Tightening torque of Clips | 0.6 Nm |
| Width | 22.5 mm |
| Height | 100 mm |
| Depth | 121 mm |
| Degree of protection of the enclosure | IP40 |
| Degree of protection of the mounting space | IP54 |
| Degree of protection of clips or terminals | IP20 |
| Ambient temperature, minimum | +0 °C |
| Ambient temperature, maximum | +55 °C |
| Storage and transport temperature, minimum | -25 °C |
| Storage and transport temperature, maximum | +70 °C |
| Resistance to vibrations | 10…55 Hz, Amplitude 0.35 mm, ± 15 % |
| Restistance to shock | 30 g / 11 ms |
| Frequency range | 50 Hz60 Hz |
| Thermal test current | 6 A |
| Rated operating voltage | 24 VAC -15% / +10%24 VDC -10%/+20%, residual ripple max. 10% |
| Rated AC voltage for controls, 50 Hz, minimum | 20.4 VAC |
| Rated control voltage at AC 50 Hz, maximum | 26.4 VAC |
| Rated AC voltage for controls, 60 Hz, minimum | 20.4 VAC |
| Rated control voltage at AC 60 Hz, maximum | 26.4 VAC |
| Rated AC voltage for controls at DC minimum | 20.4 VDC |
| Rated control voltage at DC, maximum | 28.8 VDC |
| Electrical power consumption | 5 W |
| Contact resistance, maximum | 0.1 Ω |
| Note (Contact resistance) | in new state |
| Drop-out delay in case of power failure, typically | 80 ms |
| Drop-out delay in case of emergency, typically | 20 ms |
| Pull-in delay at automatic start, maximum, typically | 100 ms |
| Pull-in delay at RESET, typically | 20 ms |
Add comment