SICK UE23-2MF2D3
| Safety technology parameters | |
|---|---|
| Integration level for security | SILCL2 (EN 62061) |
| Category | Category 3 (EN ISO 13849) |
| performance level | PL d (EN ISO 13849) |
| B 10d -value | 5.45 x 10 4 Wiring diagram (AC-15, 230 V, I = 3 A) 1.26 x 10 6 Wiring diagram (AC-15, 230 V, I = 1.5 A) 5.9 x 10 6 Wiring diagram (AC-15, 230 V, I = 0.75 A) 4.35 x 10 5 Wiring diagram (DC-13, 24 V, I = 2.5 A) 1 x 10 7 Wiring diagram (DC-13, 24 V, I = 0.63 A) |
| PFH D (average probability of dangerous outage per hour) | 3.0 x 10 -6 (EN ISO 13849) |
| T M (lifetime) | 20 years (EN ISO 13849) |
| Stop category | 0 (EN 60204-1) |
| Interfaces | |
|---|---|
| Connection type | Fixed screw connections |
| Number of acknowledgment current paths (NO contact) | 2, safety related |
| Electrical data – Operating data | |
|---|---|
| Protection class | II safe separation (EN 50178) |
| Voltage source Uv | A1, A2 |
| Signal transport | (≤ 2,4 Vss) 1) |
| Power consumption | (≤ 1 W) |
| Overvoltage category | III |
| Rated insulation voltage Ui | 300 V AC |
| Rated impulse voltage strength U imp | 6 kV |
| Test voltage | 3.5 kV (50 Hz) (EN 60439-1) |
| Electrical data – Control voltage: Y1-Y2-Y3 | |
|---|---|
| Control voltage | UV – 2 V DC … UV |
| control current | ≤ 20 mA |
| short circuit current | ≤ 250 mA |
| Short circuit protection | PTC-Resistance |
| rollback time | |
| Manuel | ≤ 70 ms |
| Automatic | ≤ 600 ms |